endress+hauser Analog conductivity sensor Condumax CLS13

endress+hauser Analog conductivity sensor Condumax CLS13

Condumax CLS13 conductivity sensor

industrial analog conductivity sensor

CLS13 sensor with warranty

Nguồn gốc:

Trung Quốc

Hàng hiệu:

E+H

Số mô hình:

CLS13

nói chuyện ngay.
Yêu cầu Đặt giá
Chi tiết sản phẩm
Làm nổi bật:

Condumax CLS13 conductivity sensor

,

industrial analog conductivity sensor

,

CLS13 sensor with warranty

Điều khoản thanh toán và vận chuyển
Số lượng đặt hàng tối thiểu
1 cái
Giá bán
USD 200
Thời gian giao hàng
7-14 ngày
Điều khoản thanh toán
T/T
Khả năng cung cấp
100 pc
Mô tả sản phẩm

What it is

  • The CLS13 is a conductive (2-electrode) conductivity sensor designed for measuring the electrical conductivity of liquids, especially very low conductivities (i.e., highly purified water / steam condensate) under high temperature and high pressure conditions.
  • It is an analog sensor (i.e., the sensor part provides a signal to a transmitter) rather than a fully digital probe.
  • It comes in different versions (cell constants, materials, explosion‐proof approvals) to suit specific applications.

 

Key Specifications & Features

Here are some of the major specs and features of the CLS13:

  • Measuring ranges (depending on version):
    • Cell constant k=0.01k = 0.01k=0.01 cm¹: 0.04 20 µS/cm (for ultra-pure water)
    • Cell constant k=0.1k = 0.1k=0.1 cm¹: 0.1 200 µS/cm
  • Process temperature: Up to approx. 250 °C (482 °F)
  • Process pressure: Up to approx. 40 bar (≈580 psi) in many versions.
  • Materials & construction:
    • Electrodes: stainless steel (material 1.4571 / AISI 316Ti in many cases)
    • Seals: Kalrez, ceramic depending on version.
    • Integration of a Pt100 temperature sensor for temperature compensation – this helps correct the conductivity reading for temperature effects.
  • Design features:
    • Coaxially arranged electrodes (inner electrode and outer electrode) to enable accurate measurements in difficult conditions.
    • Robust, durable for high-stress environments (high T, high P, maybe steam).
    • Versions with explosion protection: ATEX, FM, CSA etc for hazardous areas.
  • Installation/connection:
    • Usually connected via a dedicated transmitter (E+H transmitter) + a special measuring cable for the analog sensor.
    • Requires that the electrodes are completely immersed and wetted by the liquid (for accurate measurement) and that minimum immersion depth is observed (for example ≥50 mm).

 

Typical Applications

The CLS13 is designed for demanding industrial use, especially in power & energy or steam/water cycles. Examples:

  • Monitoring condensate in a steam system.
  • Monitoring boiler feed-water conductivity.
  • Controlling boiler blow-down (i.e., monitoring when water conductivity rises and you need to purge).
  • Any application where the conductivity is very low (i.e., ultra-pure or de-ionised water) but the process conditions are harsh (high temperature, high pressure, possibly steam).

 

Why Choose it / What Are the Benefits

  • Accuracy and reliability even at low conductivities (which can be tricky because the signal is very small).
  • Capable of withstanding harsh process conditions: high temperature, high pressure. (As mentioned above.)
  • Easy to maintain: the outer electrode is removable, stainless steel body for cleaning.
  • A quality certificate with the individual cell constant is supplied (so you know exactly the geometry/calibration of the sensor).
  • Suitable for hazardous areas (explosion prone) in some versions.

 

Things to Watch / Considerations

  • Being an analog sensor, you’ll need a compatible transmitter to convert the sensor output into a usable signal (4-20 mA or similar). It’s not a standalone digital/transmitter unit.
  • Installation matters: the electrode must be fully immersed and flow/conditions must ensure proper wetting – if there’s air pockets or poor wetting, accuracy will suffer. For ultra-pure water applications, air (or dissolved CO) can notably affect low conductivity readings.
  • Temperature compensation is integrated, but the system/ transmitter must support and use that for correct readings.
  • For ultra-pure water, even minor contamination or ingress of CO can alter readings significantly. The documentation warns about this.
  • Maintenance/corrosion of electrodes and seals over time – given the harsh conditions, it's wise to check the sensor periodically in heavy duty installations.
  • Check the exact version/part number: materials, approvals, cell constant, process connection, etc all vary.

 